Kit 1 · 9-Sheet Microsoft Excel Pack · Version 2026.3 (November 2026)
Organise air receiver hazard classifications, WHS design and item registration numbers, AS/NZS 3788:2024 inspection due dates, and AS 1271 pressure-relief valve checks in one auditable working file.
1. Who This Workbook Is For & the Decision It Supports
Built for Australian WHS managers, maintenance planners, and engineering leads managing multiple compressed air receivers across one or more sites. Instead of scattering nameplate photos, AICIP inspection reports, and relief-valve tags across email folders, this 9-sheet workbook consolidates fleet status onto a single printable A4 Executive Dashboard and flags upcoming statutory inspections before they fall overdue.
2. Sample Sheet Previews (Click Any Image to Enlarge)
Below are static sample renders from the populated 12-vessel Australian case study workbook. Both the populated reference file and a clean blank production file are included in your download.
3. Complete 9-Sheet Workbook Contents
| Sheet # | Worksheet Name | Engineering / Operational Purpose |
|---|---|---|
| Sheet 1 | 0. Start Here & Guide | Step-by-step setup workflow, colour-coded input conventions, version log, and governance boundaries. |
| Sheet 2 | 1. Executive Dashboard | A4 landscape summary with live fleet KPIs, overdue/60-day alerts, hazard distribution chart, and PCBU sign-off block. |
| Sheet 3 | 2. AS 4343 Calculator | Multi-vessel AS 4343:2014 Equation 2.1 calculator (Fc = 10 for air, Cl 2.2.8 boundary rule, kPa/MPa unit guard, state duty output). |
| Sheet 4 | 3. AS3788 Plant Register | Master asset register tracking design/item registration numbers, MDR availability, and AS/NZS 3788:2024 2y external / 4y internal due dates. |
| Sheet 5 | 4. AS 1271 PRV Register | Safety relief valve register checking PRV set pressure ≤ vessel MAWP, lead-seal status, and bench-test / replacement intervals. |
| Sheet 6 | 5. 8-State WHS Lookup | Jurisdiction reference across NSW (WHS Reg 2025 sections), QLD (RPEQ rule), VIC (design-only), WA, SA, TAS (5-yr renewal), ACT & NT. |
| Sheet 7 | 6. Imported Vessel ROI | Side-by-side cost comparison for verifying an imported CE / ASME VIII receiver (CPEng/RPEQ + NDT) vs buying a pre-verified AS 1210 tank. |
| Sheet 8 | 7. AS 1715 Breathing Air Log | Point-of-use respirator air test log validating O2, CO, CO2, oil mist, odour, and pressure dew point icing margin. |
| Sheet 9 | 8. Leak & Energy Audit | Choked-orifice ultrasonic leak register (Cd = 0.65, $0.30/kWh default tariff) + 6.5%/bar header pressure-trim calculator. |
4. Practical Boundaries & Reliance Limits
- Internal record-keeping tool, not statutory sign-off: This workbook organises your plant register and applies published AS 4343:2014 and AS/NZS 3788:2024 criteria, but it is not a substitute for design verification by a Chartered Professional Engineer (CPEng) or Queensland RPEQ, nor an in-service inspection certificate issued by a competent person / AICIP inspector.
- Single-responsibility vs multi-responsibility: If you only need to check one tank right now, use our free AS 4343 Hazard Level Calculator. If you also oversee food/pharma purity audits and compressor capex tenders, compare the Three-Kit Bundle on /workbooks/.
- Need a qualified verifier or inspector? Request a free, permission-based specialist introduction below.
Purchase Kit 1 (Instant Download)
Includes Clean Blank .xlsx, 12-Vessel Worked .xlsx, and PDF Lodgement Guide with a FirmOS Pty Ltd GST tax invoice.
Need a CPEng, RPEQ, or AS/NZS 3788 Inspector?
Free 1-to-1 introduction to a vetted independent Australian pressure-vessel engineer or inspector (Direct or Ask-First permission).