Under AS 1345-1995 (R2018), compressed air, instrument air, and vacuum lines take a Light Blue base colour (target AS 2700 B25 Aqua, tolerance B41 Bluebell) with white text.
Wherever contamination of materials for human consumption could arise (Clause 8.1 expressly lists potable water, foodstuffs, liquid foodstuffs, and medical gases, and Australian industrial plants extend this segregation to breathing-air lines alongside AS/NZS 1715), Clause 8.1 adds a Dark Blue band at least 75 mm wide (≥ 25 mm on pipes under 40 mm OD per Clause 9.3(b); preferred target B24 Harbour blue, conforming industrial shades include B21 Ultramarine), with markers placed at every valve, junction, and wall penetration at spacings no greater than 8 m indoors per Clause 9.1.
Buying bright blue anodised aluminium pipe does not tick off AS 1345-1995, and slapping a bare “AIR” sticker on a 7 bar header beside a vacuum line or nitrogen purge drop is a classic audit failure. Because compressed air, instrument air, vacuum, and pneumatic conveyors all share the exact same Light Blue colour in Table 1, bare pipe colour creates a cross-connection trap that fails the standard outright on multi-service racks and breathing-air drops.
1. What colour is compressed air pipe under AS 1345-1995?
Under AS 1345-1995 Clause 6.1(b) and Table 1, every pipe carrying only air takes the Light Blue base identification colour. That covers compressed air, instrument air, vacuum lines, ventilation ducts, and pneumatic air conveyors, while gases other than pure air (including nitrogen, LPG, process gases, and pneumatic transport of particulate solids) move to Yellow-ochre or Violet.
Table 2 splits every standard colour into a preferred paint-matching target (shown in heavy type under Clause 6.3(a)) and conforming tolerance shades for pre-coloured films or factory pipe coatings under Clause 6.3(b). For Light Blue air lines, your preferred target is AS 2700 B25 Aqua, with AS 2700 B41 Bluebell accepted within the CIE chromaticity box (luminance factor 0.30 to 0.50).
| Plant Service Line | AS 1345 Base Colour | AS 2700 Target & Tolerances (Table 2) | Legend & Chevron (Fig. 1) |
|---|---|---|---|
| Compressed air, instrument air & vacuum | Light blue | B25 Aqua (target) · B41 Bluebell | White letters · Light blue chevron |
| Nitrogen, argon, CO2, fuel & process gases | Yellow-ochre | Y44 Sand (target) · Y24, Y53, X31, X42 | Black letters · Black chevron |
| Potable, cooling & hydraulic water | Green | G21 Jade (target) · G13, G23 | White letters · Green chevron |
| Steam (live, process & exhaust) | Silver-grey | Metallic / grey finish | Black letters · Black chevron |
| Dedicated fire water & foam lines | Red | R13 Signal red (target) · R12, R14 | White letters · Red chevron |
| Acids, alkalis & corrosive gases | Violet | P23 Lilac (target) | White letters · Violet chevron |
Here’s a trap that catches workshops running shiny new ring mains: Clause 5(a) lets you leave copper, stainless steel, galvanised steel, or bare aluminium in its natural mill finish, as long as you add compliant bands or markers and no hazardous colour conflict exists.
On the flip side, installing OEM royal-blue anodised pipe for nitrogen without full Yellow-ochre markers breaches Clause 5(a), and most dark royal-blue anodised tubes fall outside Table 2’s 0.30 to 0.50 Light Blue luminance range unless verified and labelled.
Monday-standup takeaway: Walk your overhead pipe rack this week and flag any bare stainless or blue anodised line carrying nitrogen, CO2, or vacuum so it gets distinct worded labels before someone tees a workshop drop into the wrong gas.
2. When worded pipe markers and yellow hazard stripes become mandatory
Plenty of plant managers assume painting a header blue finishes the job. It doesn’t. AS 1345-1995 Clause 7.3.1 makes full worded pipe markers (not plain colour bands) a strict normative requirement (“shall be used”) in four everyday Australian plant situations:
- Two or more air services on one rack (Clause 7.3.1(b)): Because compressed air at
8 bar(g), dry-40 °Cinstrument air, breathing air, and vacuum all share Light Blue, confusing adjacent lines carries serious consequences, so every parallel pipe must carry worded labels. - Hazardous pressure or temperature services (Clause 7.3.1(a) & Clause 8.2): Wherever a special hazard to operators or maintenance crews exists, you must fit worded pipe markers alongside a yellow hazard band at least
75 mmwide (25 mmon pipes under40 mmOD) carrying equal-width diagonal black and yellow stripes (Figure 3). - Emergency shut-off clarity (Clause 7.3.1(c)): Where maintenance crews or emergency responders need instant certainty before isolating a header or breaking a flange.
- Required by another standard or regulation (Clause 7.3.1(d)): Such as AS 1596 for LP gas installations, state dangerous-goods regulations, or binding site WHS plant specifications.
So, does a standard 7 to 10 bar(g) workshop header need those yellow-and-black diagonal hazard stripes? Informative Appendix C (Section C2(e)-(f)) specifically recommends considering hazard identification whenever a gas exceeds 0.5 MPa (5 bar / 500 kPa) or an uninsulated pipe sits above 60 °C (common between the compressor discharge and aftercooler) or below -10 °C. Where a special hazard applies under Clause 8.2 and Table 2, fit the mandatory ≥ 75 mm diagonal stripe band using AS 2700 Y14 Golden yellow (target; tolerances Y12 Wattle, Y13 Vivid yellow, Y15 Sunflower); you may also add optional hazard wording such as HIGH PRESSURE on the marker per Clause 7.1(a) and optionally switch the marker’s outer border from white to yellow per Clause 7.1(c).
Monday-standup takeaway: Treat Clause 7.3.1(b) as non-negotiable on every rack where multiple Light Blue air services run side by side (plant air, vacuum, instrument air, or breathing air), use Clause 7.3.1(a)/(c) worded markers where Yellow-ochre nitrogen shares the manifold, and specify Clause 8.2 hazard stripes where risk assessments flag un-aftercooled > 60 °C discharge lines or elevated-pressure headers.
3. Breathing air (AS/NZS 1715) and food/pharma lines: the 75 mm Dark Blue band
Ordinary plant compressed air can kill an operator inside a positive-pressure blasting helmet or spray hood within minutes, because carbon monoxide has no smell and oil mist isn’t visible through a visor.
Under AS 1345-1995 Clause 8.1, wherever contamination of materials for human consumption could arise (potable water, foodstuffs, liquid foodstuffs, and medical gases), the pipe shall display an additional Dark Blue band at least 75 mm wide (25 mm on small pipes under 40 mm OD) alongside the base colour band or pipe marker.
Check the exact AS 2700 specification carefully, especially if your team works across both factories and healthcare sites. In AS 1345-1995 Table 2, the heavy-type preferred target for industrial Dark Blue bands (Clause 8.1) is AS 2700 B24 Harbour blue, while B21 Ultramarine, B15 Mid blue, and B23 Bright blue all conform inside the same CIE chromaticity space (luminance 0.10 to 0.20).
Never mix up those two codes on a hospital job, however: under AS 2896:2021 Table 3.2 and Figure 3.5, B21 Ultramarine identifies Nitrous oxide (and 50/50 nitrous oxide/oxygen with white), whereas clinical Medical air uses Black and white and Surgical tool air uses B25 Aqua.
Why do pipe markings and couplings work as a pair on industrial breathing-air sheds? Look at AS/NZS 1715:2009 Appendix F (Clause F2.3.2): it recommends (should) two-action safety couplings physically incompatible with plant-air fittings, and explicitly cites AS 1345 so nobody hooks a hood into shop air or nitrogen by mistake.
Remember too that air purity itself comes from AS/NZS 1715 Appendix A (19.5% to 22% oxygen, ≤ 10 ppm carbon monoxide, ≤ 800 ppm carbon dioxide, ≤ 1 mg/m³ oil, ≥ 170 L/min per wearer, plus regular testing with records kept, typically verified via NATA-accredited sampling as best practice), while dedicated breathing-air purification skids add catalytic CO conversion and continuous alarms.
Three specific cross-standard boundaries stop costly rework on food, pharma, and clinical sites:
- Food & beverage contact lines (FSANZ 3.2.2, SQF, BRCGS): Separate non-contact actuator headers (
ISO 8573-1:2010 [2:4:2]) from direct food-contact, dairy blowdown, or packaging air ([1:2:1]+0.2 µmsterile filtration) using distinct worded labels plus the Clause 8.1≥ 75 mmDark Blue band where cross-contamination risk exists (see our FSANZ food compressed air guide). - Hospital & dental medical gas pipelines (AS 2896:2021): AS 1345-1995 Appendix A2 explicitly recognises AS 2896 as an alternative code for healthcare. AS 2896:2021 Clause 3.7.1 & Table 3.2 specify unbroken
≥ 70 mmbands repeated every≤ 6 m, Black and white for Medical air (B25 Aqua for Surgical tool air; B21 Ultramarine is reserved for Nitrous oxide), gas names in≥ 4 mmletters prefixed with “Medical” (except surgical tool air, driving gas for venturi ejector operated suction, and venturi ejector operated suction exhaust), flow arrows, and mandatory gas-analyser verification (never labels alone). - Coaxial or jacketed lines (Clause 10) & dismantling notices (Clause 11): Coaxial pipes take the base colour of the more hazardous content with side-by-side
INNERandOUTERmarkers; pipes presenting cutting or welding hazards (such as rubber-lined or plastic lines) require a yellow-background black-letter warning notice.
Monday-standup takeaway: Pair every breathing-air and direct food-contact line with a ≥ 75 mm Dark Blue band (B24 Harbour blue or B21 Ultramarine), clear content wording, and incompatible safety couplings, then log the point in your breathing-air testing schedule.
4. Pipe marker dimensions, letter heights and 8 m spacing rules
Ordering one box of tiny 25 mm stickers for a 100 mm main header sitting 6 m up in the sawtooth roof fails both Table 3 and the visibility distance test in Clause 7.2.1. Letters must follow AS 1744 capitals (Series C or D recommended), and Clause 7.2.1 recommends at least 1 mm of letter height for every 0.4 m of viewing distance.
| Pipe Outside Diameter (OD) | Min. Patch / Band Height | Min. Letter Height (AS 1744) | Min. Marker Length | Dark Blue / Hazard Band Width |
|---|---|---|---|---|
| < 40 mm OD (Clause 7.2.3 & 9.3) | Continuous full-circumference band | ≥ 4 mm longitudinal, repeated all around | ≥ 70 mm band or marker | ≥ 25 mm wide |
| 40 to 75 mm OD (Table 3 & Cl 7.2.2) | Greater of 25 mm or 1.5× letter height | ≥ 12 mm (check 1 mm / 0.4 m sightline) | Greater of 375 mm or word + 25 mm each end | ≥ 75 mm wide |
| > 75 mm OD (Table 3 & Cl 7.2.2) | Greater of 50 mm or 1.5× letter height | ≥ 24 mm (check 1 mm / 0.4 m sightline) | Greater of 375 mm or word + 25 mm each end | ≥ 75 mm wide |
Check that worked roof-truss example before you order labels. Suppose your factory runs a 50 mm (2″) anodised aluminium ring main 6.0 m above the shop floor.
Table 3’s statutory floor for 40 to 75 mm OD pipe is a 12 mm letter on a 25 mm patch, yet at a 6.0 m reading distance Clause 7.2.1’s 1 mm per 0.4 m guide calls for 6.0 / 0.4 = 15 mm capitals (and a patch height at least 1.5 × 15 = 22.5 mm, still using the greater 25 mm Table 3 floor, or stepping up to 24 mm / 50 mm overhead wrap markers for easy floor-level reading).
Placement and spacing are equally strict under Clause 9.1 and Clause 9.4:
- Mandatory anchor points (Clause 9.1): Fit markers adjacent to all junctions, valves, service appliances, bulkheads, and wall penetrations (on both sides of the wall or partition).
- Maximum spacing (Clause 9.1): Space markers no more than
8 mapart indoors. On uninterrupted, clearly visible external pipe runs, spacing may extend up to50 m. - Patch length & base bands (Clause 7.2.2 & 9.2(b)): On pipes
≥ 40 mmOD, any marker or plain base-colour band must run at least375 mmlong (or word length plus25 mmon both ends, whichever is larger). - Multi-pipe racks (Clause 9.4): Align labels on parallel utility pipes so a maintenance technician standing on the floor can read every pipe from one viewing position.
Monday-standup takeaway: Measure your highest header truss height and count every wall penetration, isolating valve, and T-junction on your floor plan before ordering label rolls; ≤ 8 m spacing plus wall/valve anchors usually takes 25% to 40% more markers than bare straight-run maths suggests.
5. How AS 1345 ties into AS 4041 piping quotes, audits and compliance kits
Both Australian pressure-piping standard AS 4041:2006 (Clause 4.5) and pressure-equipment installation standard AS 3892-2001 (Clause 6.9) call up AS 1345 as the benchmark way to identify piping contents. Yet many turnkey pipework quotes leave labelling out completely or slap tiny unmarked arrows at the compressor outlet only, leaving you to fix wall penetrations, valve manifolds, and breathing-air bands out of pocket before an inspection.
If you are scoping a new closed-loop aluminium or 316L stainless steel line (compare installed rates per metre in our Australian compressed air piping cost guide and check bore pressure drop in our Pipe Sizing & Pressure Drop Calculator), drop these three clauses straight into your contractor RFQ:
- Supply & apply full AS 1345-1995 markers: Light Blue
B25 Aquabase markers with whiteAS 1744lettering, matching flow chevrons,375 mmminimum length (≥ 70 mmcircumferential wrap on drops< 40 mmOD), placed at all valves, junctions, both sides of wall penetrations, and≤ 8 mindoor centres. - Segregate breathing air & food/pharma drops (Clause 8.1): Distinct service text (
BREATHING AIRorFOOD-CONTACT AIR [1:2:1]),≥ 75 mmDark Blue (B24 Harbour blue/B21 Ultramarine) supplementary band, and incompatibleAS/NZS 1715safety couplings. - Apply elevated-pressure hazard stripes (Clause 8.2 / Appendix C2(f)): Include
≥ 75 mmyellow/black diagonal hazard bands on compressor discharge headers above60 °Cand nominated high-pressure lines above0.5 MPa.
If your QA, WHS, or capital team needs auditable site records alongside physical pipe labels, pick the reusable macro-free Excel kit matching your compliance gap:
- Food, Beverage & Pharma Air Audit Kit (Kit 2,
A$159.50 incl. GST): Logs point-of-useISO 8573-1purity, HACCP contact risk, filter differential pressure, and CAPA actions. - Air Receiver WHS & Plant Audit Kit (Kit 1,
A$137.50 incl. GST): TracksAS 4343vessel registration,AS/NZS 3788inspection dates,AS 1271relief valves, and plant leak registers. - Compressor Tender, Sizing & 10-Year Cost Kit (Kit 3,
A$159.50 incl. GST) & 3-Kit Bundle (A$324.50 incl. GST): Kit 3 normalises 5 supplier quotes at$0.30/kWh; the Bundle unlocks all 23 sheets across Kits 1, 2, and 3 while savingA$132. - Commercial Partner Licence (
A$874.50 incl. GST): 12-month pass for pipework contractors, AICIP inspectors, and consultants deploying co-branded registers across unlimited Australian client sites.
Monday-standup takeaway: Make AS 1345 marker installation and flow-direction chevrons an explicit practical-completion sign-off item in every pipefit RFQ so you don’t pay twice for scissor-lift hire after commissioning.
6. Free Purity & Breathing-Air Checklist + 1-to-1 Australian Specialist Introduction
Want a printable ISO 8573-1 & AS/NZS 1715 pipe-rack-walk purity checklist to clip onto your clipboard alongside the 8 m marker walk, or need an independent Australian pipework installer, NATA breathing-air tester, or WHS compliance specialist to quote your site?
If you need quotes for an AS 4041 ring-main fit-out, breathing-air purifier segregation, or a point-of-use AS/NZS 1715 or ISO 8573-1 test, share your state, pipe scope, and requirement below. CAS never sells equipment, carries inventory, or adds any markup to supplier quotes; we match your brief 1-to-1 with one suitable independent Australian provider under your chosen Ask-First or Direct permission (read how we are paid).
Food, Beverage & Pharma Air Audit Kit
7. Frequently asked questions
Is blue anodised aluminium compressed air pipe automatically compliant with AS 1345-1995?
No. Under AS 1345-1995 Clause 6.3(b) and Table 2, an as-supplied pipe colour only qualifies as the Light Blue base identification colour if it matches the CIE coordinates and 0.30 to 0.50 luminance range of AS 2700 B25 Aqua or B41 Bluebell (many royal-blue anodised pipes sit darker than Light Blue).
Even when the colour matches, Clause 7.3.1 still mandates worded pipe markers with flow arrows whenever vacuum, instrument air, nitrogen, or breathing-air pipes share the plant, or wherever elevated-pressure hazard stripes apply.
What is the exact AS 2700 colour code for compressed air vs breathing air pipes in Australia?
Under Australia’s compressed air pipe colour code (AS 1345-1995 Table 2), standard compressed air, instrument air, and vacuum use Light Blue, where the preferred target is AS 2700 B25 Aqua (tolerance B41 Bluebell) with white text.
Wherever contamination of materials for human consumption could arise (such as industrial breathing air or food lines under Clause 8.1), add a Dark Blue supplementary band at least 75 mm wide (≥ 25 mm on pipes < 40 mm OD): Table 2’s heavy-type target is B24 Harbour blue, while B21 Ultramarine, B15 Mid blue, and B23 Bright blue all conform for industrial Clause 8.1 piping (luminance 0.10 to 0.20).
Do not confuse industrial Clause 8.1 markers with hospital medical gas pipelines under AS 2896:2021, where B21 Ultramarine identifies Nitrous oxide and Medical air uses Black and white.
How far apart do AS 1345 compressed air pipe markers need to be placed?
Under Clause 9.1, markers (or ≥ 375 mm base-colour bands where worded markers aren’t triggered) must be placed adjacent to every junction, valve, service appliance, bulkhead, and wall penetration, and repeated at spacings no greater than 8 m indoors. For uninterrupted external runs visible along their full length, maximum spacing increases to 50 m.
Do medical compressed air pipelines in hospitals follow AS 1345 or AS 2896?
Hospital and clinical non-flammable medical gas pipelines follow AS 2896:2021, which AS 1345-1995 Appendix A2 explicitly recognises as an approved alternative system. Under AS 2896:2021 Clause 3.7.1 & Table 3.2, bands must be at least 70 mm wide around the full circumference, repeated every ≤ 6 m, use Black and white for Medical air (B25 Aqua for Surgical tool air; B21 Ultramarine is Nitrous oxide), carry the gas name prefixed with “Medical” (except surgical tool air, driving gas for venturi ejector operated suction, and venturi ejector operated suction exhaust) in ≥ 4 mm lettering with flow arrows, and always be verified with a gas analyser rather than labels alone.
Does AS 1345 require yellow and black hazard stripes on 7 to 10 bar compressed air lines?
Where a special hazard to operators or maintenance workers exists, Clause 8.2 mandates a yellow band or patch at least 75 mm wide (25 mm on < 40 mm OD pipes) with equal-width diagonal black and yellow stripes (preferred target Y14 Golden yellow), paired with worded markers (Clause 7.3.1(a)). Informative Appendix C (C2(e)-(f)) guides sites to consider hazard identification on gases above 0.5 MPa (5 bar) and unprotected pipes hotter than 60 °C or colder than -10 °C.
8. Related reading
- Compressed Air Piping & Distribution Systems: ring-main sizing principles, isolating valve layout, condensation control, and header velocity targets.
- Compressed Air Piping Installation Cost in Australia (2026): per-metre rates for modular aluminium, 316L stainless, and galvanised ring mains including testing and AS 1345 labelling.
- Modular Aluminium Compressed Air Piping: why pre-coated blue pipes still need AS 1345 Light Blue B25 Aqua verification and worded markers where services share a rack.
- Pipe Sizing & Pressure Drop Calculator: check DN20 to DN100 velocity, loop pressure drop, and 6 to 7% per bar energy waste at $0.30/kWh.
- Breathing Air Systems in Australia (AS/NZS 1715 & 1716): purifier train stages, catalytic CO conversion, safety couplings, and Appendix A gas ceilings.
- Breathing Air Quality Testing in Australia: NATA-accredited sampling cadence, laboratory parameters, and site WHS test records.
- FSANZ, SQF & BRCGS Food-Contact Compressed Air Guide: separating general plant headers from [1:2:1] product-contact air lines.
- Medical & Dental Compressed Air Systems: oil-free clinical air plants, AS 2896:2021 pipeline identification, and verification protocols.
- Engineering Excel Workbooks (v2026.6): reusable macro-free compliance registers for WHS vessels, food/pharma air purity, and 5-vendor tenders.